5kW Chiller; 10kW Chiller; 30kW Chiller; 60kW Chiller; 120kW Chiller
CDLJ -110℃~-50℃- Cooling capacity @-105℃2kW~120kW
- Power range14kW~768kW
- Expansion tank50L~400L
- RefrigerantR404A/R23/R14
- Weight950KG~9000KG
- Place of OriginChina
Widely used in chemical, pharmaceutical, biochemical and other industries in the field of low temperature reaction, refrigeration speed, safety and reliability.
Single fluid low-temperature refrigeration units in the pharmaceutical and chemical industry
Adopting single machine cascade refrigeration and secondary subcooling technology
Fast cooling, low cooling temperature
Control Temperature
-5~-150 ° C
Cooling method
Water-cooled/cooling
1.Temperature ranges from -5℃ ~ -150℃, can meet different temperature
- Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK. Bitzer, Copeland, Handbell, fusheng; Plate heat exchanger, Small volume, High efficiency
- Top imported cold controller; Generator cooling water circuit uses intermediate heat exchanger, improve system reliability and safety.
- DANFOSS electronic expansion valve, high precision control;
- Adopt Siemens PLC S7-200/300, LNEYA touch screen, automatic control, temperature curve display, temperature record U disk, fault alarm;
- Offer machine installation and system test, users only need to finish the installation of refrigerant and cooling water.
Used for rapid liquid refrigeration/cooling
Applied to pharmaceutical, biochemical, freeze-drying.and other high-tech industries
Support PC remote control for distances up to 200 meters. Can be integrated into the client.
Chiller’s Knowledge
How Long Does the Cold Water Machine in the Lab Need to be Cleaned?
After running for a period of time, Lab Chiller CDLJ -115℃~-50℃ requires for the protection and the maintenance of all. If the laboratory chillers lack the necessary maintenance and protection, it means the high operation defect rate of the laboratory chiller.
When running laboratory cold water machine, it needs a thorough clean for the machine to keep the laboratory machine safe and stable after using half a year’s time.
If cooling water machine for laboratory use frequency is higher, and the environment is relatively bad, to avoid the probability of all kinds of problems of industrial laboratory cold water machine, you should be able to shorten the clean time to once every three months.
The specific time about cleaning the laboratory water chiller is determined by using environment of the company. If the environment is relatively clean, the company can put off cleaning time, whereas company needs to clean it ahead of schedule in order to keep the laboratory chiller operation safe, prevent all kinds of problems in case to affect the company normal use of laboratory chiller.
Model | CDLJ-2W | CDLJ-3W | CDLJ-6W | CDLJ-10W | CDLJ-15W | CDLJ-20W | CDLJ-45W | CDLJ-60W | CDLJ-90W |
Temperature Range | -110°C~ -50°C | ||||||||
Cooling Capacity At -110°C |
2kW | 3kW | 6kW | 10kW | 15kW | 20kW | 45kW | 60kW | 120kW |
1720Kcal/h | 2580Kcal/h | 5160Kcal/h | 8600Kcal/h | 25800Kcal/h | 17200Kcal/h | 38700Kcal/h | 51600Kcal/h | 103200Kcal/h | |
Circulation Pump Info | 6.6m³/h | 6.6m³/h | 15m³/h | 15m³/h | 15m³/h | 25m³/h | / | / | / |
2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | / | / | / | |
Inlet&outlet connection size | DN-25 PN-10 |
DN-25 PN-10 |
DN-40 PN-10 |
DN-40 PN-10 |
DN-40 PN-10 |
DN-50 PN-10 |
DN-65 PN-10 |
DN-65 PN-10 |
DN-80 PN-10 |
Cooling Water at 30 degree | 10m³/h | 14m³/h | 25m³/h | 35m³/h | 45m³/h | 65m³/h | 120m³/h | 180m³/h | 360m³/h |
Expansion tank(standard) | 50L | 75L | 150L | 200L | 300L | 300L | / | / | / |
Compressor | Dorin semi-closed compressor | Dorin compressor/HANBELL、Fusheng、Bitzer screw compressor | |||||||
Operation Panel | 7-inch color touch screen display, temperature curve record | ||||||||
Control System | PLC&Module,Set temperature difference of refrigeration on & off | ||||||||
Circulation Pump | The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature | ||||||||
Circulation Pump | LNEYA Mangetic Pump | ||||||||
Evaporator | Plate heat exchanger | ||||||||
Condenser | Casing type water-cooled condenser / tube-type water-cooled condenser | ||||||||
Intermediate heat exchanger | Plate heat exchanger | ||||||||
Electric | AC contactors, intermediate relays, circuit breakers, thermal relays, etc. are Schneider / ABB brand | ||||||||
Refrigerant | R404A/R23/R14 | ||||||||
Secondary refrigerant | Ethanol, dichloromethane, heat transfer oil, etc. | ||||||||
Safety Protection | High pressure protect; water supply cut-off protection; over-current protection; leakage protection; sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. multi-safety protection | ||||||||
Level Indicator | Adopt glass liquid level indication | ||||||||
Piping material | Expansion tank, cold storage tank and circulation pipeline are all made of SUS304 | ||||||||
Case material | Channel steel + square tube + cold rolled plate sealing plate spray 7035 | ||||||||
Dimension cm | 100*150*185 | 200*145*205 | 250*145*225 | 250*145*225 | 300*160*225 | 350*160*245 | 500*200*260 | 650*200*260 | 1000*240*260 |
Power | 16kW | 25kW | 50kW | 69kW | 101kW | 136kW | 295kW | 396kW | 768kW |
dB | within 75 dB | within 90 dB | |||||||
Weight (kg) | 950kg | 1100kg | 1800kg | 2200kg | 3000kg | 3500kg | 5000kg | 6000kg | 9000kg |
Optional | Optional outside touch screen display controller (separated), the communication line distance is 10 meter | ||||||||
Optional | Optional explosion-proof touch screen control system (ExdeIIBT4), the communication line distance is 15 meter |
WhatsApp 086 13912479193
Wechat 086 15152266993
Recommended Products
SLJ -110℃~-150℃
Cooling capacity 2.5kW~11kW Evaporation area 2㎡~7.8㎡ Power range 12kW~36kW
LD -80℃~-30℃
Cooling capacity @-75℃ 4kW~180kW Power range 14kW~588kW
LN -60℃~-10℃
Cooling capacity @-55℃ 6kW~180kW Power range 14kW~300kW
LJ -45℃~-10℃
Cooling capacity @-20℃ 12kW~360kW Power range 12kW~270kW