Electronic Pump Test temperature Simulation
KRY 0℃~100℃ 1&6S- Heating Power15kW~38kW
- Cooling capacity18kW~60kW
- Power range38kW~82kW
- Temperature accuracy±0.5℃
- Flow rate output2~50 L/min
- RefrigerantR404A/R507C/R125/N40
- Weight900KG~1950KG
KRY 0℃~100℃ 1&6S (3 sets of auxiliary temperature control, pressure/flow controlled separately)
Product’s Description
Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.
Equipped with a powerful circulation pump while ensuring the delivery of highly viscous liquids.
Control the flow output with variable frequency regulation or proportional control valve to achieve high precision control total range 5%~100% adjustment.
The testing part is connected to a platform adapter, and the thermal mediumpasses through the testing part to provide a high and low temperatureenvironment. The testing part goes through a temperature change to check itsperformance.The temperature change can be recorded.
The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
When performing a tolerance test, it usually takes an infinite loop.
Multi channel independent temperature control
The system adopts LNEYA PLC control, with simple menu navigation, a 7 inch color large screen, and comprehensive and multifunctional image display of important data information. The newly added safety measures ensure continuous unmanned operation. All relevant operating status data is continuously monitored and visualized on the touch screen. It supports independent control of one to many channels, and each group can be set independently.
Variable frequency regulation
The variable frequency pump can adjust the circulating liquid pressure and flow rate, achieving high-precision control of 5%~100% of the total range adjustment.
Client A
Client B
By using a variable frequency pump, the motor speed can be controlled at the appropriate value corresponding to the required pressure.
Test temperature of main test items of vehicle electronics:
IC test conditions for locomotives: -40℃~125℃, wind blowing, sun exposure, high vibration;
Instrument panel operation test test conditions: -40℃~85℃;
Motor controller test conditions: operating test temperature: 40 ℃ ~ 110 ℃;
Satellite positioning (GPS) Test conditions: high temperature operation test temperature: 85℃; low temperature operation test temperature: -40℃;
Compound vibration: -40℃~80℃;
Obviously the best solution is for the test house to have temperature simulation system equipment.
Motor and motor controller
Motor coroller durabilitytest, motor and motorcontroller bracket
Charge point test
On load charging experiment and charging communication interactive test
OBC/DC-DC
Model test, power test. Durability test
Power battery system
Battery pack charge and discharge test, fuel cell test
Model | KRY-A25W/6S | KRY-A38W/6S | KRY-A60W/6S | |
Temp. Range | 0℃~+100℃ | |||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | |
Flow control/Group | 2~20 L/min | 2~20 L/min | 2~20 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 6 Groups | 6 Groups | 6 Groups | |
pressure control/Group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
flow pressure description | The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized) | |||
Heating power | 15kW | 25kW | 38kW | |
cooling capacity | 100℃ | 25kW | 38kW | 60kW |
20℃ | 25kW | 38kW | 60kW | |
5℃ | 18kW | 27kW | 42kW | |
compression | Emerson Valley Wheel Compressor | |||
expansion | Electronic Expansion Valve | |||
oil distributor | Emerson | |||
Dry filter, Pressure | Danfoss | |||
Evaporator | Plate heat exchanger | |||
Ciriulating pump | Nangfang centrifugal pump can be selected with imported brand magnetic pump | |||
Frequency | Delta | |||
Flow, Pressure sensor | German brand flowmeter, johnson Controls pressure | |||
input, Display | 5 inch color touch screen \ PLC controller | |||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | |||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | ||||
is it a fully closed system | The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature. | |||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | |||
Connection size | There are six groups of inlet and outlet,ZG3/4 | |||
Cooling water at 20C° | 6000L/H | 9000L/H | 15000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | |||
Power 380V50HZ | 38kW | 55kW | 82kW | |
Dimension cm | 200*145*205 | 200*145*205 | 200*145*205 | |
Weight | 900kg | 1200kg | 1950kg | |
Optional | 220V 60HZ three phase 460V 60H three phase | |||
Optional | Extend to -40~+135℃ | |||
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, | |||
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. | ||||
Optional | When the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving |