As the temperature rises, or the frequency of use of the chiller is relatively high, it will cause the temperature of the chiller to be different to frop at a high level. If the service time of water-cooled chiller has reached more than half a year, then the operating temperature is too high, which is… Read more The treatment method of chiller temperature is difficult to drop
Tag: chiller
Low pressure fault analysis of industrial chillers
The low pressure alarm of chillers and chillers is a common problem in the use of industrial chillers. There are several possible reasond for the failure. 1. There is leakage in the refrigeration system. When the control temperature f the normal temperature chller is above 5 degrees and the low pressure gauge is below 2… Read more Low pressure fault analysis of industrial chillers
Application scope of industrual chillers
Industrial water chiller is a refrigeration unit is a refrigeration unit that provides frozen water. It can provide frozen watger or chemical solution of -30 ~20 degrees according to the needs of users. It is especially suitable for electroplating, medicine, chemical, plastic, food additives and other production lines on the cooling and enterproses, institutions need… Read more Application scope of industrual chillers
The working priciple of chillers
The chiller uses the limited refrigerant int he closed refrigeration system, repeatedly compressing, condensing, expanding and evaporating the refrigeratn, and constantly absorbs heat and vaporizes in the evaporator to refrigerate and cool down. The chiller is composed of compressor, condenser, evaporator, evaporator, expansion valve, circulating water pump, electric control system and rack, etc. In the… Read more The working priciple of chillers
The price of rapid temperature control system – thermal cycle controller
When using LNEYA rapid temperature control system, regular maintenance plans can be made and regular maintenance can be carried out to reduce the failure rate. Rapid temperature control system – cleaning the condenser dust of the thermal cycle controller The condenser should be maintained regular monthly. The dust attached to the condenser heat net can… Read more The price of rapid temperature control system – thermal cycle controller
What do the LNEYA chiller fault codes mean? What is the solution?
Q: What is the fault code of the chiller? Answer: E1 means extremely high indoor temperature alarm, E2 means extremely high temperature alarm, E3 means extremely low temperature alarm, E4 means indoor temperature controller failure, E5 means water temperature sensor failure, E6 means water output alarm, etc. . The fault codes of industrial chillers are… Read more What do the LNEYA chiller fault codes mean? What is the solution?