There are probably the following reasons for insufficient heat exchange in the evaporator. First, the evaporator water flow is insufficient. The main factors that cause this phenomenon are that the pump is broken or there is a froeign body in the pump impelier, ot the water pump inlet pipe leaks caused by insufficient water flow.… Read more Reason for serious insufficient heat exchange in evaporator
Tag: ultra low temperature chiller
Cleaning instructions for ultra-low temperature refrigeration units used by pharmaceutical and chemical companies
Long-term operation of the ultra-low temperature freezing unit will cause thick scale on the surface of the condenser, which will interfere with the normal operation of the large-scale pharmaceutical and chemical ultra-low temperature freezing unit. For example, if it makes its work efficiency low or easy to damage, then it is necessary to clean up.… Read more Cleaning instructions for ultra-low temperature refrigeration units used by pharmaceutical and chemical companies
A safe place for cryochillers in the production area
Cryochiller units are used more frequently in summer. Some manufacturers may replace new equipment, or some companies are just established in the food industry or the chemical industry, and industrial types need cryochiller units to cool down the reaction process of the production project. There are many requirements for the placement location. When placing the cryochiller units,… Read more A safe place for cryochillers in the production area
The importance of temperature control in the processing of hemp plants
The legalization of industrial hemp in Europe, America and other countries has increased the demand for equipment for hemp processing. Cannabis eventually comes in the form of CBD extract. In order to convert the plant into a concentrate for medicines and supplements, the factory must carefully control the temperature during the extraction and distillation process.… Read more The importance of temperature control in the processing of hemp plants
The savior of the cannabis extraction industry Cannabis CBD Chillers | CBD Chiller
The hemp, cannabis, and CBD/THC industry is taking off. Efficient and effective equipment is required to maintain the quality of CBD and THC oils. Oils can go rancid and break down without proper preservation. Re-outfitting a refrigerator or alcohol chiller might have worked for your competitors for a while, Heat is a destructive element when… Read more The savior of the cannabis extraction industry Cannabis CBD Chillers | CBD Chiller
From what aspects should we consider the use of circulating chillers?
Circulating coolers are a popular choice for temperature-critical applications because they provide stable temperature control, constant flow and constant pressure control. Many process heating systems require cooling and heating. For example, many conveyor heating zones have cooling zones. Injection molding requires a lot of heat dissipation. And the reactor is usually jacketed with cold water.… Read more From what aspects should we consider the use of circulating chillers?
Method for controlling shutdown of water cooled chiller of single reaction kettle
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to… Read more Method for controlling shutdown of water cooled chiller of single reaction kettle
Precautions for operation of ethylene glycol utra-low temperature chiller at minus 30 degrees
The minus 30 degree ethylene glycol utra-low temperature chiller is a device that is used more in the pharmaceutical and chemical industry. When using it, you need to pay attention to its operating specifications to operate it. If used improperly, it will cause a short service life. Refrigerant leakage will not only affect the… Read more Precautions for operation of ethylene glycol utra-low temperature chiller at minus 30 degrees
Precautions for customers installing Lneya’s cryogenic industrial chillers
One. Low temperature industrial chillers need to pay attention to some installation requirements when installing 1. The cryogenic industrial chiller should be installed directly in a horizontal position, do not install it upside down or diagonally 2. Low-temperature industrial chillers generate heat during operation, and should ensure the circulation of cooling air. There should be… Read more Precautions for customers installing Lneya’s cryogenic industrial chillers
Precautions for maintenance of cooling systems for laboratory instruments
Industrial refrigeration units dedicated to laboratory instruments are used more in the pharmaceutical and chemical industries, and care must be taken when using them. The daily maintenance of refrigeration units for laboratory instruments is mainly reflected in the following aspects: 1. Condenser The high-temperature and high-pressure Freon of the refrigeration system of the industrial refrigeration… Read more Precautions for maintenance of cooling systems for laboratory instruments